Home
Product Catalog
News
Contact Us

Product Catalog 

100ul-10ml multi-channel syringe pump module for auto analyzer

  • 100ul-10ml multi-channel syringe pump module for auto analyzer
  • 100ul-10ml multi-channel syringe pump module for auto analyzer
  • 100ul-10ml multi-channel syringe pump module for auto analyzer
  • 100ul-10ml multi-channel syringe pump module for auto analyzer
Model No.︰2000
Brand Name︰Jury
Country of Origin︰China
Unit Price︰US $ 250 / pc
Minimum Order︰1 pc
Share on:

 Total 17 Related Items 
Prev1213141516Next

Product Description

2000 Series syringe assembly is a high precision liquid quantitative module developed by our professional R&D team. It has compact structure, wear resistance and long service life. It can be completely maintenance free in 2 million service cycles. Long travel, high transmission accuracy, accurate quantification of suction and drainage liquids. The plunger is made of ceramics or stainless steel with good wear resistance and high regents compatibility.

The specifications of single channel body covers various capacity requirements of 100ul-10ml, and different specifications of body can be replaced as a whole, with good compatibility.

Multi-channel module realizes multi-channel simultaneous suction and drainage of liquid, saving space and cost. The number of channels can vary from 1 to 10, and the size and number of channels can be customized according to customer needs.

Model selection of single syringe:

Syringe identification code

displacement

Thread form

Syringe model

Travel (MM)

Side hole direction

S03

100UL

1/4-28UNF

1010-60-U2R-MKL

60

Right

S04

100UL

1/4-28UNF

1010-60-U2L-MKL

60

Left

S05

250ul

1/4-28UNF

1025-60-U2R-MKL

60

Right

S06

250ul

1/4-28UNF

1025-60-U2L-MKL

60

Left

S16

250ul

10-32UNF

1025-60-N2R-MKL

60

Right

S07

500ul

1/4-28UNF

1050-60-U2F-MKL

60

Front

S08

500ul

1/4-28UNF

1050-60-U2L-MKL

60

Left

S36

500ul

1/4-28UNF

1050-60-U2R-MKL

60

Right

S09

1ml

1/4-28UNF

1100-60-U-MKZ

60

/

S22

1ml

M6

1100-60-M-MKZ

60

/

S10

2.5ml

1/4-28UNF

1250-60-U-MKZ

60

/

S11

2.5ml

1/4-28UNF

1250-60-U2L-MKZ

60

Left

S13

5ml

1/4-28UNF

1500-60-U-MKZ

60

/

S54

5ml

1/4-28UNF

1500-60-U2F-MKZ

60

Front

S14

7.5ml

1/4-28UNF

1750-60-U-MKZ

60

/

S15

10ml

1/4-28UNF

101A-60-U-MKZ

60

/

S69

10ml

1/4-28UNF

101A-60-U2R-MKZ

60

Right

S17

10ml

10-32UNF

101A-60-N-MKZ

60

/

 

Model selection of multi-channel syringes:

Syringe identification code

displacement

Thread form

Syringe model

Travel (MM)

Side hole direction

S102

2.5ml+10ml

1/4-28UNF

1002-60-U-201

60

/

S83

250ul+10ml

1/4-28UNF

1002-60-U-205

60

/

S23

3*1ml

1/4-28UNF

1003-60-U-307

60

/

S93

2.5ml+10ml+250ul

1/4-28UNF

1003-60-U-302

60

/

S79

3*1ml

1/4-28UNF

1003-45-U-308

45

/

S24

4*1ml

1/4-28UNF

1004-60-U-402

60

/

S101

375ul-3*600ul

1/4-28UNF

1004-30-U-404

30

/

S77

5*1ml

1/4-28UNF

1005-60-U-504

60

/

S100

5*1ml

1/4-28UNF

1005-45-U-503

45

/

S26

6*1ml

1/4-28UNF

1006-60-U-602

60

/

S95

6*600ul

1/4-28UNF

1006-60-U-601

60

/

S86

8*100ul

1/4-28UNF

1008-60-U-801

60

/

S87

8*1ml

1/4-28UNF

1008-60-U-803

60

/

S88

8*2.5ml

1/4-28UNF

1008-60-U-804

60

/

S99

8*250ul

1/4-28UNF

1008-25-U-805

25

/

...

...

...

...

...

 

Note: The specifications of syringes can be customized according to customer requirements.

3.Specification

 

Effective stroke L(mm)

25、30、40、45、60...

Lead P(mm)

2.5、4、5、6...

Stepping motor step angle º

1.8

Motor current (A)

0.7

1.2

2

Displacement V(ul)

Determined by syringe displacement

Lifecycle

2 million

Linear distance per step of motor S(mm)

0.01250.02、0.025、0.03...

fluid volume per step (ul)

V*P/200L

Accuracy of suction and drainage

2%

Cv

0.2%

Working pressure(MPa)

0.3

Cavity material

POM(white)PTFE

Plunger material

Special ceramics316L

Sealing material

superhigh molecular polymer

Working medium

Clear water, oil, acid, alkali, etc.

Thread Interface Form

1/4-28 UNFM6、10-32UNF

Remark:

Note 1: The nominal accuracy of suction and drainage is determined at a range of no less than 10% displacement.

Note 2: The nominal CV is measured at a range of no less than 10% displacement.

Note 3: Other specifications can also be customized, including travel, lead, displacement, sealing material and other parameters.

 

 

Payment Terms︰TT
Product Image





Related Products
Two dimensional puncture mechancial transmission part for auto analyzer
Two dimensional puncture mechancial transmission part for auto analyzer
US $ 280
Z&R Axis mechanical transmission part for clinical diagnosis analyzer
Z&R Axis mechanical transmission part for clinical diagnosis analyzer
US $ 260
Mechanical transmission part for IVD medical device
Mechanical transmission part for IVD medical device
US $ 280
Mutti-way solenoid valve group for COD analyzer
Mutti-way solenoid valve group for COD analyzer
US $ 150




Home  |  Product Catalog  |  News  |  Contact Us  |  Sitemap  |  Mobile Version

Powered by DIYTrade.com  Build your FREE website !
Find Best Price For China Products !