Model No.︰2000
Brand Name︰Jury
Country of Origin︰China
Unit Price︰US $ 250 / pc
Minimum Order︰1 pc
2000 Series syringe assembly is a high precision liquid quantitative module developed by our professional R&D team. It has compact structure, wear resistance and long service life. It can be completely maintenance free in 2 million service cycles. Long travel, high transmission accuracy, accurate quantification of suction and drainage liquids. The plunger is made of ceramics or stainless steel with good wear resistance and high regents compatibility.
The specifications of single channel body covers various capacity requirements of 100ul-10ml, and different specifications of body can be replaced as a whole, with good compatibility.
Multi-channel module realizes multi-channel simultaneous suction and drainage of liquid, saving space and cost. The number of channels can vary from 1 to 10, and the size and number of channels can be customized according to customer needs.
Model selection of single syringe:
Syringe identification code |
displacement |
Thread form |
Syringe model |
Travel (MM) |
Side hole direction |
S03 |
100UL |
1/4-28UNF |
1010-60-U2R-MKL |
60 |
Right |
S04 |
100UL |
1/4-28UNF |
1010-60-U2L-MKL |
60 |
Left |
S05 |
250ul |
1/4-28UNF |
1025-60-U2R-MKL |
60 |
Right |
S06 |
250ul |
1/4-28UNF |
1025-60-U2L-MKL |
60 |
Left |
S16 |
250ul |
10-32UNF |
1025-60-N2R-MKL |
60 |
Right |
S07 |
500ul |
1/4-28UNF |
1050-60-U2F-MKL |
60 |
Front |
S08 |
500ul |
1/4-28UNF |
1050-60-U2L-MKL |
60 |
Left |
S36 |
500ul |
1/4-28UNF |
1050-60-U2R-MKL |
60 |
Right |
S09 |
1ml |
1/4-28UNF |
1100-60-U-MKZ |
60 |
/ |
S22 |
1ml |
M6 |
1100-60-M-MKZ |
60 |
/ |
S10 |
2.5ml |
1/4-28UNF |
1250-60-U-MKZ |
60 |
/ |
S11 |
2.5ml |
1/4-28UNF |
1250-60-U2L-MKZ |
60 |
Left |
S13 |
5ml |
1/4-28UNF |
1500-60-U-MKZ |
60 |
/ |
S54 |
5ml |
1/4-28UNF |
1500-60-U2F-MKZ |
60 |
Front |
S14 |
7.5ml |
1/4-28UNF |
1750-60-U-MKZ |
60 |
/ |
S15 |
10ml |
1/4-28UNF |
101A-60-U-MKZ |
60 |
/ |
S69 |
10ml |
1/4-28UNF |
101A-60-U2R-MKZ |
60 |
Right |
S17 |
10ml |
10-32UNF |
101A-60-N-MKZ |
60 |
/ |
Model selection of multi-channel syringes:
Syringe identification code |
displacement |
Thread form |
Syringe model |
Travel (MM) |
Side hole direction |
S102 |
2.5ml+10ml |
1/4-28UNF |
1002-60-U-201 |
60 |
/ |
S83 |
250ul+10ml |
1/4-28UNF |
1002-60-U-205 |
60 |
/ |
S23 |
3*1ml |
1/4-28UNF |
1003-60-U-307 |
60 |
/ |
S93 |
2.5ml+10ml+250ul |
1/4-28UNF |
1003-60-U-302 |
60 |
/ |
S79 |
3*1ml |
1/4-28UNF |
1003-45-U-308 |
45 |
/ |
S24 |
4*1ml |
1/4-28UNF |
1004-60-U-402 |
60 |
/ |
S101 |
375ul-3*600ul |
1/4-28UNF |
1004-30-U-404 |
30 |
/ |
S77 |
5*1ml |
1/4-28UNF |
1005-60-U-504 |
60 |
/ |
S100 |
5*1ml |
1/4-28UNF |
1005-45-U-503 |
45 |
/ |
S26 |
6*1ml |
1/4-28UNF |
1006-60-U-602 |
60 |
/ |
S95 |
6*600ul |
1/4-28UNF |
1006-60-U-601 |
60 |
/ |
S86 |
8*100ul |
1/4-28UNF |
1008-60-U-801 |
60 |
/ |
S87 |
8*1ml |
1/4-28UNF |
1008-60-U-803 |
60 |
/ |
S88 |
8*2.5ml |
1/4-28UNF |
1008-60-U-804 |
60 |
/ |
S99 |
8*250ul |
1/4-28UNF |
1008-25-U-805 |
25 |
/ |
... |
... |
... |
... |
... |
|
Note: The specifications of syringes can be customized according to customer requirements.
3.Specification
Effective stroke L(mm) |
25、30、40、45、60... |
||
Lead P(mm) |
2.5、4、5、6... |
||
Stepping motor step angle (º) |
1.8 |
||
Motor current (A) |
0.7 |
1.2 |
2 |
Displacement V(ul) |
Determined by syringe displacement |
||
Lifecycle |
2 million |
||
Linear distance per step of motor S(mm) |
0.0125、0.02、0.025、0.03... |
||
fluid volume per step (ul) |
V*P/200L |
||
Accuracy of suction and drainage |
2% |
||
Cv |
0.2% |
||
Working pressure(MPa) |
0.3 |
||
Cavity material |
POM(white)、PTFE |
||
Plunger material |
Special ceramics、316L |
||
Sealing material |
superhigh molecular polymer |
||
Working medium |
Clear water, oil, acid, alkali, etc. |
||
Thread Interface Form |
1/4-28 UNF、M6、10-32UNF |
||
Remark: Note 1: The nominal accuracy of suction and drainage is determined at a range of no less than 10% displacement. Note 2: The nominal CV is measured at a range of no less than 10% displacement. Note 3: Other specifications can also be customized, including travel, lead, displacement, sealing material and other parameters. |
Payment Terms︰ TT